电动门调试方法及接线 |
添加时间:2021/11/1 14:59:49 浏览次数: |
电动门调试方法及接线 Debugging method and wiring of EMG electric door
热控圈 2018-03-18
Thermal control circle March 18, 2018
汽机技术
Turbine technology
传播知识,分享精华!
Spread knowledge and share essence.
关注
follow
1,首先删除出先前设定的限位,方法如下:
1. First delete the previously set limit, as follows:
先按下Learn
(LT)按扭,在把S1拨扭开关移至Learn位置。大约过十秒就地指示灯(开、关两只指示灯)开始闪亮。这表示执行前一进入调试状态。大约在过20秒两指示灯熄灭,这表示正在删除先前设定限位。大约在过35秒,便可松开Learn
(LT)按扭,两指示灯回重新闪亮,此时先前设定已被删除,并且此时执行器进入了Learn (调试)状态。 2,行程开、关设定,方法如下:
First press the learn (LT) button, and move the S1 knob switch to
the learn position. After about ten seconds, the local indicator light
(on and off two indicators) starts to flash. This indicates that the
debugging state is entered before execution. After about 20 seconds, the
indicator light turns off, indicating that the previously set limit is
being deleted. After about 35 seconds, you can release the learn (LT)
button, and the two indicator lights will flash again. At this time, the
previous settings have been deleted, and the actuator is in the learn
state. 2. Set the stroke on / off as follows:
A,
设定关限位:把S2拨到CLOSE,执行器电动到全关位置。(注:执行器随时可以通过把S2拨到STOP位置使其停止)然后,把S2按扭拨回STOP位置,在按下Learn功能键同时,再次把S2拨到CLOSE位置,此时CLOSE由闪烁变常亮。说明关限位行程已设置完毕。
A. Set the closing limit: set S2 to close, and the actuator is
powered to the fully closed position. (Note: the actuator can stop at
any time by turning S2 to the stop position) then, turn S2 button back
to the stop position, press the learn function key, and then turn S2 to
the close position again, at this time, the close will turn on from
flashing. It indicates that the closing limit stroke has been set.
B,
设定开限位:把S2拨到OPEN,执行器电动到全关位置。(注:执行器随时可以通过把S2拨到STOP位置使其停止)然后,把S2按扭拨回钢制闸门 钢坝 保定轻钢别墅 保定平面设计培训 保定室内设计培训 保定办公家具 保定空调维修 STOP位置,在按下Learn功能键同时,再次把S2拨到OPEN位置,此时OPEN由闪烁变常亮。说明开限位行程已设置完毕。
B. Set open limit: set S2 to open, and electric actuator to full
close position. (Note: the actuator can stop at any time by turning S2
to the stop position) then, turn S2 button back to the stop position,
press the learn function key, and then turn S2 to the open position
again, at this time, the open turns on from flashing. Indicates that the
opening limit stroke has been set.
注:1)当执行器离开设定终端位置时,开关指示灯又会闪烁。只有两个终端位置都设置完毕,并退出Learn状态。指示灯才能在两个终端位置正常指示。
Note: 1) when the actuator leaves the set terminal position, the
switch indicator will flash again. Only two terminal positions are set